Aim RSS-214

Aim RSS-214 Heat Stress Monitor

High Reliability - Dust and splash proof construction provide a solid Mean Time Between Failure (MTBF) rate of 171,000 hours.

Fast Responding - Direct reading of outflow and inflow WBGT, WB, and GT values. Globe equivalent temperatures typically requires three minutes.

Accurate - Calculates to 1/100th degree and displays to 1/10th degree.

Easy Operation - At the push of a button, the RSS-214 calculates time weighted mean BGT, metabolic rate and work rest ratios.

Optional Data Logging:

Software provides ease of data storage and retrieval and calculates time weighted mean WBGT and time weighted metabolic rates.

View more product details Download PDF

Specifications
Calibration Range Verified
Range 25°C, 45°C, 60°C
Range can be extended to 100°C through an optional extension cable
WBGT Value Calculations WBGT (outdoor) = 0.7 Wet Bulb + 0.2 GT + 0.1 Dry Bulb
WBGT (indoor) = 0.7 Wet Bulb + 0.3 GT
Accuracy
Resolution 0.1°C
Electronics including Temperature Coefficient +/-0.1°C
Measurement within Calibration Range +/-0.4°C
Sensors
Globe Temperature Patented construction provides characteristics identical to 6" Vernon Globe
Dry Bulb Ambient air temperature
Wet bulb Wick covered sensor with reservoir, wetted with de-ionized or distilled water
Battery
Type Rechargeable 9V Ni-Cad
Life 17 hours of continuous operation
Charger Plugs into monitor, can operate unit while charging, recharges in less than 14 hours
Response Time
90% Responded Level Less than 2.2 minutes
95% Responded Level Less than 4.5 minutes, for most practical purposes, the 95% response time can be considered as fully responded
Electronics Warm-up Less than 3 seconds, provided the sensors are acclimatized, readings are valid as soon as the meter reading stabilizes